1.
Int J Cardiol ; 222: 832-840, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27522385

RESUMO

BACKGROUND & AIMS: Although Absorb Bioresorbable Vascular Scaffolds (A-BVS) are routinely used in the Asia-Pacific, there is little information on patient selection or deployment technique here. This document investigates the experiences of leading interventional cardiologists from the Asia-Pacific region with a focus on patient characteristics, deployment techniques and management. METHODS AND RESULTS: A detailed questionnaire was distributed to 28 highly-experienced interventional cardiologists ('Authors') from 13 Asia-Pacific countries. The results were discussed at a meeting on patient selection, technical consideration, deployment practices and patient management. Potential patient benefits of Absorb compared to metallic DES, the learning curve for patient selection and preparation, device deployment, and subsequent patient management approaches are presented. CONCLUSIONS: Current practices are derived from guidelines optimized for European patients. Differences in approach exist in the Asia-Pacific context, including limited access to imaging and frequency of occurrence of complex lesions. Nevertheless, the use of the Absorb BVS ('Absorb') in certain Asia-Pacific countries has flourished and practices here are continuing to mature.


Assuntos
Implantes Absorvíveis/estatística & dados numéricos , Prótese Vascular/estatística & dados numéricos , Cardiologistas/estatística & dados numéricos , Cardiologia , Doença da Artéria Coronariana/cirurgia , Alicerces Teciduais/estatística & dados numéricos , Ásia , Humanos , Desenho de Prótese
2.
BMJ Open ; 6(2): e010028, 2016 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-26888727

RESUMO

OBJECTIVES: To evaluate, in the FLEX Registry, clinical outcomes of an ultrathin (60 µm) biodegradable polymer-coated Supraflex sirolimus-eluting stent (SES) for the treatment of coronary artery disease. Additionally, to determine the vascular response to the Supraflex SES through optical coherence tomography (OCT) analysis. SETTING: Multicentre, single-arm, all-comers, observational registry of patients who were treated with the Supraflex SES, between July 2013 and May 2014, at nine different centres in India. PARTICIPANTS: 995 patients (1242 lesions) who were treated with the Supraflex SES, between July 2013 and May 2014, at nine different centres in India. A total of 47 participants underwent OCT analysis at 6 months' follow-up. INTERVENTIONS: Percutaneous coronary intervention with Supraflex SES, PRIMARY AND SECONDARY OUTCOME MEASURES: The primary endpoint-the rate of major adverse cardiac events (defined as a composite of cardiac death, myocardial infarction (MI), target lesion revascularisation (TLR))-was analysed during 12 months. RESULTS: At 12 months, the primary endpoint occurred in 36 (3.7%) of 980 patients, consisting of 18 (1.8%) cardiac deaths, 16 (1.6%) MI, 7 (0.7%) TLR and 2 (0.2%) cases of non-target lesion target vessel revascularization. In a subset of 47 patients, 1227 cross-sections (9309 struts) were analysed at 6 months by OCT. Overall, a high percentage of struts was covered (98.1%), with a mean neointimal thickness of 0.13 ± 0.06 µm. CONCLUSIONS: The FLEX Registry evaluated clinical outcomes in real-world and more complex cohorts and thus provides evidence that the Supraflex SEX can be used safely and routinely in a broader percutaneous coronary intervention population. Also, the Supraflex SES showed high percentage of stent strut coverage and good stent apposition during OCT follow-up.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea , Sistema de Registros , Sirolimo/administração & dosagem , Implantes Absorvíveis , Idoso , Doenças Cardiovasculares/mortalidade , Feminino , Humanos , Índia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Revascularização Miocárdica/estatística & dados numéricos , Neointima/patologia , Polímeros , Tomografia de Coerência Óptica
3.
Artigo em Inglês | MEDLINE | ID: mdl-26585397

RESUMO

BACKGROUND: Drug-eluting stents (DES) have been shown to reduce the rate of acute complications and the need for subsequent revascularization in cases where single-vessels are treated. The performance of DES in patients with multivessel disease and complex lesions, however, remains controversial. This study assessed and compared clinical outcomes following single vs. multivessel percutaneous coronary intervention (PCI), using the Supraflex sirolimus-eluting stent (SES), in an all-comers patient population. METHODS: We conducted retrospective, multicenter, all-comers, observational study of 995 patients, who underwent either single-vessel PCI (n=769 patients; group-I) or multivessel PCI (n=226 patients; group-II), treated with the biodegradable polymer coated Supraflex SES, between July-2013 and May-2014 at nine different centers in India. Pre-specified primary endpoint, rate of major adverse cardiac events (MACE) [defined as composite of cardiac death, myocardial infarction (MI), target lesion revascularization (TLR) and non-target lesion target vessel revascularization (non-TL TVR)], was analyzed during 12 months after the post-index procedure. We also analyzed the incidence of stent thrombosis (ST) as a safety endpoint during the follow-up period, as defined by the Academic Research Consortium (ARC). RESULTS: Of the whole study group, 1,242 lesions were treated in 995 patients (mean age 61.6±10.8 years; 80.0% male) with average stent length of 26.8±9.3 mm. Multivessel PCI patients were older, had a higher prevalence of arterial hypertension, were smoker, had a family history of coronary artery disease, previous stroke and previous PCI compared to single-vessel PCI patients. Follow-up was available in 99.0% (761/769) of patients with single-vessel intervention and 96.9% (219/226) of patients with multivessel intervention at the end of 12 months. In-hospital MACE was similar for both the groups [group-I, 3 (0.4%) vs. group-II, 1 (0.4%); p=1.000]. The observed MACE for group-I and group-II, at 30 days, 6 and 12 months follow-up were 9 (1.2%) vs. 2 (0.9%); p=1.000, 15 (2.0%) vs. 7 (3.2%); p=0.302 and 24 (3.2%) vs. 12 (5.5%); p=0.109, respectively. The cumulative incidence curves for MACE showed no significant differences between the two groups, at the end of 12 months (p=0.109). CONCLUSION: Our study shows that use of the Supraflex SES in single and multivessel coronary artery disease produces good clinical outcomes during 12 months of follow-up with a low rate of revascularization, despite complex lesion morphology.


Assuntos
Antibacterianos/uso terapêutico , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Sirolimo/uso terapêutico , Idoso , Antibacterianos/administração & dosagem , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Sirolimo/administração & dosagem , Trombose/etiologia , Resultado do Tratamento
4.
J Invasive Cardiol ; 24(5): E99-100, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22562931

RESUMO

Coronary artery fistula is a rare condition where a fistulous communication exists between the coronary artery and a cardiac chamber or vein. Mostly they are of congenital origin, but rarely may be acquired due to trauma, post cardiac surgery or angioplasty, or very rarely, because of coronary aneurysm rupture. Ours is an interesting case of a post-coronary artery bypass graft surgery status with a fistula in second obtuse marginal branch of left circumflex coronary artery draining into left ventricle aneurysm. We explore possible causes including erosion of the thin aneurysmal wall into coronary lumen. Given the history of previous surgical revascularization, it may be a contained rupture and the possibility of pulsatile effect of the obtuse marginal branch eroding into the thin wall aneurysm is considered.


Assuntos
Aneurisma Cardíaco/etiologia , Fístula Vascular/etiologia , Idoso , Angiografia Coronária , Oclusão Coronária/epidemiologia , Estenose Coronária/epidemiologia , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/epidemiologia , Humanos , Masculino , Placa Aterosclerótica/epidemiologia , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/epidemiologia